LORO-X Double sockets
If a pipe section without socket remains after cutting to length, it can be complemented to a socket pipe again by using the LORO-X double socket. The double socket should be glued onto the remaining pipe using the LORO-X sealing element and LORO-X adhesive. (In frost-endangered areas, sockets directed against the flow direction, including double sockets, are not permitted)
| LORO-X Double sockets | |||||||
| DN 40 | DN 50 | DN 70 | DN 80 | DN 100 | DN 125 | DN 150 | DN 200 |
| 00560.040X | 00560.050X | 00560.070X | 00560.080X | 00560.100X | 00560.125X | 00560.150X | 00560.200X |
LORO-X Push-in sockets with long socket
For pipe installation between 2 fixed points, the long socket offers a greater insertion depth for length compensation. It does not replace a permanent compensator for thermal expansion, as the lubricant and sealing element create a fixed connection after a short time.
| LORO-X Push-in socket withlong sockets | |||||||
| DN 40 | DN 50 | DN 70 | DN 80 | DN 100 | DN 125 | DN 150 | DN 200 |
| 00810.040X | 00810.050X | 00810.070X | 00810.080X | 00810.100X | 00810.125X | 00810.150X | 00810.200X |
LORO-X Push-in socket
with extra deep insertion
For length compensation and installation between 2 fixed points. Promotes tool-free working on the construction site, as the need for on-site pipe cutting can be reduced by supplementing a "too short" standard pipe length with the push-in socket, instead of cutting a "too long" standard pipe length.
| LORO-X Push-in socket | |
| DN 70 | DN 100 |
| 00813.070X | 00813.100X |
LORO-X Short socket
LORO-X Connector with short socket and reduced insertion end
| LORO-X Push-in socket |
| DN 70 |
| 08019.070X |