LORO-X Pipes with 1 socket

The nominal length (l) of the pipes is specified without the socket length and can therefore be used for counting the pipes in an assembled state. Example: Nominal length 1000 mm + 70 mm socket = 1070 mm pipe outer dimension. 

The flow capacity for gravity flow with gradient can be found here.

LORO-X Pipes with one socket
l (mm) DN 32 DN 40 DN 50 DN 70 DN 80 DN 100 DN 125 DN 150 DN 200
250 01401.032X 01401.040X 01401.050X 01401.070X 01401.080X 01401.100X 01401.125X 01401.150X 01401.200X
500 01301.032X 01301.040X 01301.050X 01301.070X 01301.080X 01301.100X 01301.125X 01301.150X 01301.200X
750 01211.040X 01211.050X 01211.070X 01211.080X 01211.100X 01211.125X 01211.150X 01211.200X
1000 01201.032X 01201.040X 01201.050X 01201.070X 01201.080X 01201.100X 01201.125X 01201.150X 01201.200X
1500 01111.032X 01111.040X 01111.050X 01111.070X 01111.080X 01111.100X 01111.125X 01111.150X 01111.200X
2000 01101.032X 01101.040X 01101.050X 01101.070X 01101.080X 01101.100X 01101.125X 01101.150X 01101.200X
2500 01004.040X 01004.050X 01004.070X 01004.080X 01004.100X 01004.125X 01004.150X 01004.200X
2750 01005.050X 01005.070X 01005.080X 01005.100X 01005.125X
3000 01001.040X 01001.050X 01001.070X 01001.080X 01001.100X 01001.125X 01001.150X 01001.200X
4000 01011.050X 01011.070X 01011.080X 01011.100X 01011.125X 01011.150X 01011.200X
5000 01013.070X 01013.080X 01013.100X 01013.125X 01013.150X
6000 01014.070X 01014.080X 01014.100X 01014.125X 01014.150X

LORO-X Pipes with long socket (rainwater downpipe for balconies)

For length compensation during pipe installation between 2 fixed points, e.g. for already installed downpipes between balconies or offsets on roof terraces.

The total dimension of the pipe consists of the nominal dimension and the standard socket insertion depth. The remainder of the long socket serves for length compensation of the pipes during installation. Example DN70, 2500mm long: Total dimension 2555 mm - standard socket 55 mm = 2500 mm.

LORO-X Pipes with long socket, for balcony drainage
l (mm) DN 32 DN 40 DN 50 DN 70 DN 80 DN 100 DN 125 DN 150 DN 200
2500 01002.050X 01002.070X 01002.100X
2750 01003.050X 01003.070X 01003.100X

LORO-X Pipes with long socket for main/emergency combination DN 50

With LORO-X pipes with long socket for main/emergency combination, the deviating pipe length dimension according to the dimensional drawing must be observed! In this version, the long socket is calculated completely in addition to the nominal dimension.

LORO-X Pipe with long socket,made of steel, hot-dip galvanised, additionally coated inside,DN 50
l (mm)
DN 50
500 01302.050X
1000 01203.050X
2000 01108.050X

Online calculation